Vestigo Petroleum SDN BHD Wellhead Platform

Overview

The study aims to assess the integrity and stability of the caisson foundation due to the installation of a new internal conductor inside the caisson.

 

Engineering Services

Performed engineering studies as below:

  • Literature Review,
  • Develop a soil model based on the existing soil investigation data,
  • Parameterization for FEM modelling, based on provided boring log and design parameters prepared for pile design,
  • 3D Finite Element Method (FEM) stress simulations using Plaxis 3D will be performed to analyze the impact of installation,
  • Estimate caisson foundation capacity after installation of the new conductor,
  • Generate p-y, t-z and q-z curves based on the foundation assessment for inputs in the pile-soil interaction analysis.
  • Update the TNAG SACS inplace model incorporating updated p-y, t-z and q-z curves and additional loads due to new infill well inside caisson.
  • Run inplace analysis and evaluate the impact of new infill well inside caisson to the overall structural integrity including caisson stability.